Transformer Oil I HPCL

Transformer Oil I :

Detail Description Of HPCL Transformer Oil I

HP TRANSFORMER OIL I is inhibited type transformer oil meeting IS:12463. Inhibited transformer oils can extend the service life of transformer oil.

It also meets IS:335-2018 TYPE II INHIBITED.

Typical Physical Characteristics Of Transformer Oil I
Test Method Typical
Appearance A representative sample of the oil shall be examined in a 100 mm thick layer at 27ºC Clear and transparent  and free from suspended matter or sediments
Density at 29.5ºC, g/cc IS 1448 [P : 16] : 1990 0.8279
Kinematic viscosity, IS 1448 [P : 25] : 1976
at 27ºC 16.46
at 40ºC 11.76
Interfacial tension at 27ºC, IS 6104 : 1971 0.044
Flash point Pensky-Marten (closed), ºC IS 1448 [P : 21] : 1992 148
Pour point, ºC IS 1448 [P : 10] : 1970 -18
Neutralization value
a) Total acidity, IS 1448 [P : 2] : 1967 Nil
b) Inorganic acidity/alkalinity Nil
Corrosive sulphur Annex B of IS 335 - 1993 Non Corrosive
Electric strength 72
(breakdown voltage) IS 6792 : 1992
a) New unfiltered oil,
b) After filtration, min Note 2
Dielectric dissipation factor (tan δ) IS 6262 : 1971 0.00025/2.05 DC
at 90ºC,
Specific resistance (resistivity) IS 6103 : 1971
a) At 90ºC, 750 × 1012 ohm-cm
b) At 27ºC, 7650 × 1012 ohm-cm
Oxidation stability IS 12422 - 1988
a) Neutralization value Nil
after oxidation, Nil
b) Total sludge, after oxidation,
Oxidation stability (Rotating IS 12958 - 1990 210
Bomb test), minutes
Oxidation inhibitor, percent by, wt IS 13631 - 1993 0.26
Water content, ppm IS 13567 - 1992 9

If you wish to buy Transformer Oil I of HPCL from Mumbai, India then please email to sales@lubeoilcompany.com or call/whatsapp +919870666888.

Transformer Oil I, HPCL in India
We can give you the best cost prices to buy Transformer Oil I compared to all dealers, suppliers, vendors, wholesalers, retailers, traders, resellers and distributors in Mumbai, Navi Mumbai, Bhiwandi, Thane in Maharashtra and all India.

Inhibited Type Transformer Oil Transformer Oil I, HPCL in India
We can also ship Transformer Oil I to all these states of India Andhra Pradesh, Arunachal Pradesh, Assam, Bihar, Chhattisgarh, Goa, Gujarat, Haryana, Himachal Pradesh, Jharkhand, Karnataka, Kerala, Madhya Pradesh, Maharashtra, Manipur, Meghalaya, Mizoram, Nagaland, Odisha, Punjab, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, Uttar Pradesh, Uttarakhand, West Bengal, Andaman and Nicobar Islands, Chandigarh, Dadra and Nagar Haveli and Daman and Diu, Delhi, Jammu and Kashmir, Ladakh, Lakshadweep and Puducherry.